NSN 6130-01-363-6655 · NIIN 013636655 · FSC 6130
NO DASHES 6130013636655
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: PROCESSOR UNIT
Technical characteristics
38 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 14.880 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 5.000 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 9.000 |
| ADZC | ENVIRONMENTAL PROTECTION | GENERAL PURPOSE |
| AGAV | END ITEM IDENTIFICATION | PROCESSOR UNIT |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SECOND ALTERNATE OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | FIRST ALTERNATE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 115.0 |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 230.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 12.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 12.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 70.0 |
| CBBL | FEATURES PROVIDED | OVER VOLTAGE PROTECTOR AND EMI FILTER |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 10.0 |
| CWGH | OUTPUT CURRENT RATING | FOURTH POWER OUTPUT DC AMPERES NOMINAL 200.0 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL 19.0 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 10.0 |
| CWHC | OUTPUT CONTROL LOCATION | FOURTH POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | THIRD POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | FIRST POWER OUTPUT FRONT PANEL |
| CWHC | OUTPUT CONTROL LOCATION | SECOND POWER OUTPUT FRONT PANEL |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 |
| CWHJ | OUTPUT CONNECTION TYPE | FOURTH POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | THIRD POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | FIRST POWER OUTPUT TERMINAL STRIP |
| CWHJ | OUTPUT CONNECTION TYPE | SECOND POWER OUTPUT TERMINAL STRIP |
| CWHM | INPUT CURRENT RATING | SECOND ALTERNATE OPERATING POWER RQMT AC AMPERES NOMINAL 300.0 |
| CWHM | INPUT CURRENT RATING | FIRST ALTERNATE OPERATING POWER RQMT AC AMPERES NOMINAL 200.0 |
| CWHQ | INPUT CONNECTION TYPE | FIRST ALTERNATE OPERATING POWER RQMT TERMINAL STRIP |
| CWHQ | INPUT CONNECTION TYPE | SECOND ALTERNATE OPERATING POWER RQMT TERMINAL STRIP |
| CWHT | INPUT CONNECTION QUANTITY | 1 |
| CWKG | VENTILATION DESIGN TYPE | CONVECTION |
| FEAT | SPECIAL FEATURES | REFERANCE PROCESSOR UNIT T.O.31R2-2GSQ235,FIG 8-4 INDX 183 |