NSN 5945-01-356-4134 · NIIN 013564134 · FSC 5945
NO DASHES 5945013564134
In Stock
RELAY,ELECTROMAGNETIC
Relays and Solenoids
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 0.375 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.300 |
| ABMK | OVERALL WIDTH | INCHES MAXIMUM 0.375 |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | SINGLE WINDING OHMS NOMINAL 64.0 |
| APNP | DUTY TYPE | CONTINUOUS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | SINGLE MOUNTING FACILITY TERMINAL 1 |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| CRXH | TIME DELAY | FIXED RELEASE TIME SECONDS MAXIMUM 0.003 |
| CRXH | TIME DELAY | FIXED OPERATE TIME SECONDS MAXIMUM 0.006 |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 5.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | LAMP LOAD MILLIAMPERES DC 100.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD MILLIAMPERES AC 600.0 AND AMPERES DC 1.0 |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | INDUCTIVE LOAD MILLIAMPERES DC 200.0 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 115.0 AND DC 28.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS WIRE LEAD 8 |