NSN 6130-01-369-3394 · NIIN 013693394 · FSC 6130
NO DASHES 6130013693394
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: SCOPE SHIELD II PROGRAM
Technical characteristics
28 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 10.000 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.250 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 15.000 |
| AGAV | END ITEM IDENTIFICATION | SCOPE SHIELD II PROGRAM |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | FIRST ALTERNATE OPERATING POWER RQMT SINGLE |
| ANPM | INPUT PHASE | SECOND ALTERNATE OPERATING POWER RQMT SINGLE |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 220.0 |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 120.0 |
| APNX | INPUT VOLTAGE RATING | THIRD ALTERNATE OPERATING POWER RQMT DC VOLTS NOMINAL 24.0 |
| APNX | INPUT VOLTAGE RATING | FOURTH ALTERNATE OPERATING POWER RQMT DC VOLTS NOMINAL 12.0 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL 28.0 |
| APTQ | INPUT FREQUENCY RATING | FIRST ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 60.0 |
| APTQ | INPUT FREQUENCY RATING | SECOND ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 60.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS -30.0 TO 60.0 |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT DC AMPERES NOMINAL 9.5 |
| CWGH | OUTPUT CURRENT RATING | SECOND POWER OUTPUT DC AMPERES NOMINAL 3.0 |
| CWGH | OUTPUT CURRENT RATING | THIRD POWER OUTPUT DC AMPERES NOMINAL 3.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | SECOND POWER OUTPUT MILLIVOLTS PEAK 150.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | FIRST POWER OUTPUT MILLIVOLTS PEAK 300.0 |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | THIRD POWER OUTPUT MILLIVOLTS PEAK 30.0 |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 |
| CWHJ | OUTPUT CONNECTION TYPE | SECOND POWER OUTPUT CONNECTOR, RECEPTACLE |
| CWHJ | OUTPUT CONNECTION TYPE | FIRST POWER OUTPUT CONNECTOR, RECEPTACLE |
| CWHJ | OUTPUT CONNECTION TYPE | THIRD POWER OUTPUT CONNECTOR, RECEPTACLE |
| FEAT | SPECIAL FEATURES | THE INPUT SUPPLY CABLES SHALL BE 30 FEET LONG,INPUT CONNECTOR:MS3102A32-8P,OUTPUT CONNECTOR MS3102A20-16S; HAS OVER VOLTAGE AND SHORT CIRCUIT PROTECTION AND IS ELECTROSTATIC SENSITIVEDEVICE |