NSN 6665-01-016-1921 · NIIN 010161921 · FSC 6665
NO DASHES 6665010161921
In Stock
RADIACMETER
Hazard-Detecting Instruments and Apparatus
Technical characteristics
11 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABFF | FURNISHED ITEMS | CARRYING CASE |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 8.750 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 4.500 |
| AMKD | INDICATOR TYPE | METER |
| AMRM | RADIATION TYPE AND FUNCTION | ALPHA RAYS DETECTS AND ALPHA RAYS MEASURES |
| AMRX | DETECTING ELEMENT TYPE | SCINTILLATION |
| APCB | PORTABILITY | PORTABLE |
| APPN | ACCURACY IN PERCENT | AT FULL SCALE 0.0 TO 10.0 |
| CTJX | DOSE RATE PER HOUR | MILLIRAD 0.0 TO 0.2 |
| FEAT | SPECIAL FEATURES | OPERATING RANGES: 4 LINEAR OVERLAPPING RANGES 0 TO 800,0 TO 8,000 AND 0 TO 80,000 CPM FOR BOTH GM AND SCINTILLATION PROBES PLUS 0 TO 800,000 CPM FOR SCINTILLATION RPOBES; DOSE RATE RANGES 0 TO 0.2,0 TO 2 AND 0 TO 20 MR/HR;TEMP LIMITS 30 TO 50 DEG C;HUMIDITY LIMITS 0 TO 99%; BATTERY 2 D CELLS; DIMENSIONS 22.2 CM LONG,11.4 CM WIDE,12.8 CM HIGH |
| MATT | MATERIAL | CASE ALUMINUM OR STEEL |