Home / MS parts / Electrical & Electronic Components / NSN 5950-00-649-8349
NSN 5950-00-649-8349  ·  NIIN 006498349  ·  FSC 5950
NO DASHES 5950006498349
In Stock

TRANSFORMER,POWER

Coils and Transformers

Technical characteristics

21 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.000
ADATBODY WIDTHINCHES NOMINAL 3.375
ADAUBODY HEIGHTINCHES NOMINAL 3.125
AARGRELIABILITY INDICATORNOT ESTABLISHED
ACZBFREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
CQJXNOMINAL THREAD SIZESINGLE GROUP INCHES 0.190
ADAQBODY LENGTHINCHES NOMINAL 3.938
AKPVMOUNTING FACILITY QUANTITY4
AXGYMOUNTING METHODSINGLE GROUP THREADED STUD(S)
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.125
ABKWOVERALL HEIGHTINCHES NOMINAL 4.188
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 416.00
THSDTHREAD SERIES DESIGNATORSINGLE GROUP UNF
TTQYTERMINAL TYPE AND QUANTITYTURRET 9
BPLCWINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 2
CMLPTHREAD QUANTITY PER INCH32
CWJSWINDING OPERATING VOLTAGESINGLE COMPONENT ALL SECONDARY AC VOLTS NOMINAL 260.00
AKNAINCLOSURE TYPEHERMETICALLY SEALED
CRBZWINDING OPERATING CURRENTSINGLE COMPONENT ALL SECONDARY MILLIAMPERES AC MAXIMUM 123.0
ACZXWINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE