Home / MS parts / NSN 5925-00-482-5772
NSN 5925-00-482-5772  ·  NIIN 004825772  ·  FSC 5925
NO DASHES 5925004825772
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

36 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ADATBODY WIDTHINCHES MINIMUM 2.245 AND INCHES MAXIMUM 2.255
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.555 AND INCHES MAXIMUM 1.565
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.655 AND INCHES MAXIMUM 1.665
AJECBOSS HEIGHTINCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.135
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.835 AND INCHES MAXIMUM 1.845
AKPXPOLE QUANTITY3
ADAQBODY LENGTHINCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
FREQFREQUENCY IN HERTZ600.0
MATTMATERIALCASE PLASTIC
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755
AFJNFRAGILITY FACTORMODERATELY RUGGED
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 13.0
TTQYTERMINAL TYPE AND QUANTITYTAB, SOLDER LUG 6
AAQLBODY STYLE
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 250.0