NSN 5950-01-120-9187 · NIIN 011209187 · FSC 5950
NO DASHES 5950011209187
In Stock
TRANSFORMER,POWER AUTOTRANSFORME
Coils and Transformers
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 5.500 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 4.250 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 60.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT THREE PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-WYE |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 8.000 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 5.750 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 3.000 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| AXGY | MOUNTING METHOD | SINGLE GROUP BRACKET(S) AND THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY, FIXED AUTOTRANSFORMER TYPE 1 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.190 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE PRIMARY INPUT MILLIAMPERES AC MAXIMUM 500.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY OUTPUT AC VOLTS NOMINAL 70.00 AND AC VOLTS NOMINAL 74.00 AND AC VOLTS NOMINAL 78.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY INPUT AC VOLTS NOMINAL 115.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNF |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 13 |