NSN 6105-00-635-2358 · NIIN 006352358 · FSC 6105
NO DASHES 6105006352358
In Stock
MOTOR,DIRECT CURRENT
Motors, Electrical
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 4 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ABRV | KEYWAY DEPTH | SINGLE END INCHES NOMINAL 0.2500 |
| AAJT | OVERALL HEIGHT | INCHES 26.438 |
| CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 17.000 |
| CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES 23.500 |
| BKPQ | INCLOSURE SPECIFICATION | MIL-STD-108 |
| CBBL | FEATURES PROVIDED | VERTICAL MOUNTING POSITION |
| ABWV | SHAFT DIAMETER | SINGLE END INCHES NOMINAL 1.8750 |
| AKCT | SHAFT ROTATION DIRECTION | SINGLE END CLOCKWISE OR COUNTERCLOCKWISE |
| AXGY | MOUNTING METHOD | FIXED BASE |
| CWDY | TEMP RATING | AMBIENT CELSIUS 40.0 AND OPERATING CELSIUS 50.0 |
| CWFX | ROTOR SPEED RATING IN RPM | LOW FULL LOAD 1310.0 AND HIGH FULL LOAD 1750.0 |
| AAJU | OVERALL LENGTH | INCHES 40.000 |
| ANPZ | ENCLOSURE FEATURE | DRIPPROOF-15 DEG |
| AXCP | WINDING TYPE | SHUNT WOUND |
| CWCS | LENGTH OF SHAFT FROM HOUSING | SINGLE END INCHES 4.000 |
| CWDM | SHAFT CENTER TO MOUNTING SURFACE DISTANCE | SINGLE END INCHES 14.000 |
| BFMF | COOLING METHOD | SELF-VENTILATED |
| AAJV | OVERALL WIDTH | INCHES 33.500 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 230.0 |
| CWHZ | SHAFT END CHARACTERISTIC | SINGLE END SINGLE STYLE A9 |
| ABRR | KEYWAY WIDTH | SINGLE END INCHES NOMINAL 0.5000 |
| BKPB | CURRENT RATING METHOD | LOAD |