Home / MS parts / NSN 6130-01-259-0375
NSN 6130-01-259-0375  ·  NIIN 012590375  ·  FSC 6130
NO DASHES 6130012590375
In Stock

POWER SUPPLY

Converters, Electrical, Nonrotating

Application: TRANS MODULE STATION

Technical characteristics

42 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 10.000
ABKWOVERALL HEIGHTINCHES NOMINAL 2.750
ABMKOVERALL WIDTHINCHES NOMINAL 9.000
ADZCENVIRONMENTAL PROTECTIONFUNGUS PROOF
AGAVEND ITEM IDENTIFICATIONTRANS MODULE STATION
AKAEMAXIMUM OPERATING ALTITUDE RATINGFEET 15000.0
AKWCELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
ANPMINPUT PHASESINGLE OPERATING POWER RQMT SINGLE
APNXINPUT VOLTAGE RATINGSINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 103.5 AND AC VOLTS MAXIMUM 129.0
APPAOUTPUT VOLTAGE RATINGTHIRD POWER OUTPUT DC VOLTS NOMINAL 7.1
APPAOUTPUT VOLTAGE RATINGFIRST POWER OUTPUT DC VOLTS NOMINAL 17.0
APPAOUTPUT VOLTAGE RATINGNINTH POWER OUTPUT DC VOLTS NOMINAL 5.0
APPAOUTPUT VOLTAGE RATINGSEVENTH POWER OUTPUT DC VOLTS NOMINAL 5.0
APPAOUTPUT VOLTAGE RATINGTENTH POWER OUTPUT DC VOLTS NOMINAL -5.0
APPAOUTPUT VOLTAGE RATINGSECOND POWER OUTPUT DC VOLTS NOMINAL 15.0
APPAOUTPUT VOLTAGE RATINGFIFTH POWER OUTPUT DC VOLTS NOMINAL 7.1
APPAOUTPUT VOLTAGE RATINGFOURTH POWER OUTPUT DC VOLTS NOMINAL 7.1
APPAOUTPUT VOLTAGE RATINGSIXTH POWER OUTPUT DC VOLTS NOMINAL 5.0
APPAOUTPUT VOLTAGE RATINGEIGHTH POWER OUTPUT DC VOLTS NOMINAL 5.0
APTQINPUT FREQUENCY RATINGFIRST ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 380.0 AND HERTZ MAXIMUM 420.0
APTQINPUT FREQUENCY RATINGTHIRD ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 47.5 AND HERTZ MAXIMUM 52.5
APTQINPUT FREQUENCY RATINGSECOND ALTERNATE OPERATING POWER RQMT HERTZ MINIMUM 57.0 AND HERTZ MAXIMUM 63.0
AYNHOPERATING AMBIENT TEMP RANGECELSIUS -10.0 TO 55.0
CBBLFEATURES PROVIDEDOVER VOLTAGE PROTECTOR AND INPUT TO OUTPUT ISOLATION AND INPUT TO CASE ISOLATION AND OUTPUT TO CASE ISOLATION
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CWGHOUTPUT CURRENT RATINGFIFTH POWER OUTPUT DC AMPERES NOMINAL 7.0
CWGHOUTPUT CURRENT RATINGNINTH POWER OUTPUT DC AMPERES NOMINAL 2.3
CWGHOUTPUT CURRENT RATINGSEVENTH POWER OUTPUT DC AMPERES NOMINAL 2.3
CWGHOUTPUT CURRENT RATINGTENTH POWER OUTPUT DC AMPERES NOMINAL -0.1
CWGHOUTPUT CURRENT RATINGSIXTH POWER OUTPUT DC AMPERES NOMINAL 4.4
CWGHOUTPUT CURRENT RATINGFOURTH POWER OUTPUT DC AMPERES NOMINAL 7.0
CWGHOUTPUT CURRENT RATINGEIGHTH POWER OUTPUT DC AMPERES NOMINAL 2.3
CWGHOUTPUT CURRENT RATINGSECOND POWER OUTPUT DC AMPERES NOMINAL 1.9
CWGHOUTPUT CURRENT RATINGTHIRD POWER OUTPUT DC AMPERES NOMINAL 7.0
CWGHOUTPUT CURRENT RATINGFIRST POWER OUTPUT DC AMPERES NOMINAL 3.7
CWHFOUTPUT CONNECTION QUANTITY13
CWHJOUTPUT CONNECTION TYPESINGLE POWER OUTPUT TERMINAL STRIP
CWHQINPUT CONNECTION TYPESINGLE OPERATING POWER RQMT TERMINAL STRIP
CWHTINPUT CONNECTION QUANTITY2
CWKGVENTILATION DESIGN TYPECONVECTION
CWWYPOWER SUPPLY EFFICIENCY LINE72.0
FEATSPECIAL FEATURESNUCLEAR HARDENED ITEM