Home / MS parts / NSN 5925-00-686-3298
NSN 5925-00-686-3298  ·  NIIN 006863298  ·  FSC 5925
NO DASHES 5925006863298
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

34 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND CORROSION RESISTANT AND EXPLOSION RESISTANT AND FUNGUS RESISTANT AND DUSTPROOF AND MOISTURE RESISTANT AND SAND RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
AAQLBODY STYLE
ABXDBUSHING LENGTHINCHES MINIMUM 0.235 AND INCHES MAXIMUM 0.265
ADAQBODY LENGTHINCHES MAXIMUM 1.094
ADATBODY WIDTHINCHES MAXIMUM 0.750
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.469
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 7.5 AND AMPERES DC 7.5
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
THSDTHREAD SERIES DESIGNATORUNS
TTQYTERMINAL TYPE AND QUANTITYTAB W/SCREW 2
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.673 AND INCHES MAXIMUM 0.735
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.840
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 55.000
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S25244
CTJSUNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 1.813
FREQFREQUENCY IN HERTZ400.0
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-5809
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 3500.0 AND DC 6000.0

Cross-references

26 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
700-001-7 1/276374
MP702H76374
956C560-379500
AS2524481343
MS25244-7-1/281343
CVC2523-780378
AS5809181343
CVC2523-781640
D6761-4-782647
700-002-70581640
6761-4-782647
MIL-C-580981349
956C560-383843
5925PL14977529009H
0436-712393568
04306-712393568
MS25244-796906
MS25244-7.596906
956C560-399167
5925006863298A00AM
369A4590-502731
AS252440U583
AS580910U583
MS25244-7-1/20U583
SAE-AS580910U583
1172888919200

Supersedes

This item replaces cancelled NIINs 005438092 · 005831092 · 007290576 · 008939798. An older drawing citing one of those numbers resolves here.