NSN 5950-00-783-3761 · NIIN 007833761 · FSC 5950
NO DASHES 5950007833761
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.750 |
| FEAT | SPECIAL FEATURES | 1 PRIMARY; 7 SECONDARIES |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 300.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 2.00 AND AC VOLTS NOMINAL 10.00 AND AC VOLTS NOMINAL 11.00 AND AC VOLTS NOMINAL 16.00 AND AC VOLTS NOMINAL 22.00 AND AC VOLTS NOMINAL 36.00 |
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 7 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.112 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MINIMUM 30.0 AND MILLIAMPERES AC MAXIMUM 400.0 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY AMPERES AC MAXIMUM 4.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.125 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.750 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.750 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 190.0 |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.375 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 135.0 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OIL |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 60.00 |
| ACZX | WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 21.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 84.00 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 24 |
Cross-references
2 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| C504000059 | 88818 |
| D2480 | 90095 |